LOW AIR PRESSURE WARNING BUZZER WILL NOT SHUT OFF (AIR PRESSURE GAUGES AT NORMAL SYSTEM PRESSURE)
Table 2-3. Electrical Troubleshooting (Contd).

TM-9-2320-272-24-1 Truck 5-Ton 6x6 M939 M939A1 M939A2 Series Trucks (Diesel) Manual
Page Navigation
  230    231    232    233    234  235  236    237    238    239    240  
TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 2. Test continuity at air pressure switches.
Step 1.  Start engine (TM 9-2320-272-10) and allow air pressure to reach normal operating
pressure.
Step 2. Set multimeter to RX1 for continuity reading.
Step 3. Disconnect lead 57 at air pressure switch B.
Step 4. Touch positive lead of multimeter to contact end of lead 57 and negative lead of
multimeter to frame ground.
a. If continuity is present, go to step 5.
b. If continuity is not present, replace lead 57 (para. 3-131).
Step 5.  Connect lead 57 to air pressure switch B.
Step 6. Disconnect lead 578 from air pressure switch A.
Step 7. Touch positive lead of multimeter to contact end of lead 578 and negative lead of
multimeter to frame ground.
a. If continuity is present, go to step 8.
b. If continuity is not present, replace lead 578 (para. 3-131).