Test 5. Test starter solenoid contractors
Test 7. Test positive cable 6 from batteries to starter solenoid

TM-9-2320-272-24-1 Truck 5-Ton 6x6 M939 M939A1 M939A2 Series Trucks (Diesel) Manual
Page Navigation
  177    178    179    180    181  182  183    184    185    186    187  
TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 6. Test negative cable 7 voltage drop from batteries to starter.
Step 1.  Set multimeter to lo-volt range.
Step 2.  Connect multimeter positive lead to terminal stud on end plate of starter and negative
lead to grounding point at batteries.
Step 3.  Crank engine and observe multimeter. A voltage reading exceeding 0.4 volt indicates
loose or corroded connection(s).
Clean and tighten connections at batteries, starter, and chassis (para. 3-124).