• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
ENGINE AND VEHICLE ELECTRlCAL SYSTEM MALFUNCTlONlNG
SPECIFIC GRAVITY WILL NOT INCREASE TO 1.280 UNDER CHARGE

TM-9-2320-272-24-1 Truck 5-Ton 6x6 M939 M939A1 M939A2 Series Trucks (Diesel) Manual
Page Navigation
  168    169    170    171    172  173  174    175    176    177    178  
TM 9-2320-272-24-1
Table 2-3. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BATTERY SYSTEM
2. BATTERlES ARE HOT, ELECTROLYTE IS BOILING, OR EXCESSIVE USE OF WATER
NOTE
If STE/ICE is available, perform NG50 - Charging Circuit Tests
(para. 2-24).
Check electrolyte temperature and specific gravity and note reading (TM 9-6140-200-14).
a. If temperature is over 120F (49C) and specific gravity is 1.280 or greater, batteries
are being overcharged. Go to generating system troubleshooting (malfunction 9,
test 1).
b. If battery temperature is over 120F (49C), but specific gravity is 1.236-1.260,
recharge batteries (TM 9-6 140-200-14).
END OF TESTING!
2-97