POWER SYSTEM OPERATION
Fuel System (Dual Tank) Operation.

TM-9-2320-272-24-1 Truck 5-Ton 6x6 M939 M939A1 M939A2 Series Trucks (Diesel) Manual
Page Navigation
  29    30    31    32    33  34  35    36    37    38    39  
TM 9-2320-272-24-1
1-21. POWER SYSTEM OPERATION (Contd)
Key  Item and Function
1  RAIN CAP - Prevents rain and large objects from entering air intake system.
2  AIR INTAKE EXTENSION TUBE - Routes air to air intake system. Can be removed for shipping.
3  STACK-TO-AIR INTAKE EXTENSION TUBE - Routes air to air cleaner and is high enough to
keep intake opening above fording level.
4  STACK-TO-AIR CLEANER ELBOW - Flexible connection between air stack and air cleaner.
5  AIR CLEANER - Filters dirt and dust from air.
6  HUMP HOSE - Flexible connection between air cleaner and air cleaner outlet tube.
7  AIR CLEANER OUTLET TUBE - Routes air from air cleaner to intake manifold.
8  INTAKE MANIFOLD - Distributes air to combustion chambers in each cylinder head (M939/Al
series only).
9  AIR CLEANER INDICATOR - Shows red when engine air filter needs servicing.
10  TURBOCHARGER - Mounts on exhaust manifold and uses spent exhaust gases to drive impeller
and pressurize air entering aftercooler (M939A2 series only).
11  AFTERCOOLER - Distributes compressed air from turbocharger to combustion chambers while
cooling air intake out of turbocharger (M939A2 series only).