12-34. 3-PHASE AND 400 HZ RECEPTACLES REPLACEMENT
THIS TASK COVERS:
a. 3-Phase Receptacle Removal
c. 3-Phase Receptacle Installation
b. 400 Hz Receptacle Removal
d. 400 Hz Receptacle Installation
INITIAL SETUP
APPLICABLE MODELS
EQUIPMENT CONDITION
M820, M820A1, M820A2
Parking brake set (TM 9-2320-260-10).
Battery ground cable disconnected (para. 4-48).
REFERENCES (TM)
TM 9-2320-260-10
TM 9-2320-260-20P
NOTE
Tag all wires for installation.
a. 3-Phase Receptacle Removal
1. Remove two screws (4) and cover (3) from receptacle (5).
2. Remove two screws (2) and receptacle (5) from receptacle box (1).
3. Remove four screws (6) and wires (7) from receptacle (5).
b. 400 Hz Receptacle Removal
NOTE
Tag all wires for installation.
1. Remove screw (11) and cover (10) from receptacle (12).
2. Remove two screws (9) and receptacle (12) from receptacle box (8).
3. Remove three screws (13) and wires (14) from receptacle (12).
c. 3-Phase Receptacle Installation
1. Install four wires (7) on receptacle (5) with four screws (6).
2. Install receptacle (5) on receptacle box (1) with two screws (2).
3. Install cover (3) on receptacle (5) with two screws (4).
I
d. 400 Hz Receptacle Installation
1. Install three wires (14) on receptacle (12) with three screws (13).
2. Install receptacle (12) on receptacle box (8) with two screws (9).
3. Install cover (10) on receptacle (12) with screw (11).