MICROBRAKE LOCK WIRING REPLACEMENT

TM-9-2320-260-20 5-Ton 6x6 M809 Series Trucks (Diesel) Truck Cargo: 5-Ton 6x6 M813 (2320-00-050-8902) (EIC:BSB); Manual
Page Navigation
  537    538    539    540    541  542  543    544    545    546    547  
TM 9-2320-260-20
I
4-53. FLOODLIGHT WIRING HARNESS REPLACEMENT (Contd)
10.
Connect floodlight wiring harness (17) to connector (16).
11.
Install clip (25) on crossmember (23) with screw (21) and new locknut (24).
Install connector (16) on clip (25).
12.
13.
Route floodlight wiring harness (17) along frame rail (22) and under cab (31).
Insert floodlight wiring harness (17) through retainer (38), grommet (30), and hole in firewall (27).
14.
15.
Connect leads (28) and (17) to connectors (29).
NOTE
Assistant will help with steps 16 and 17.
16.
Place grommet (30) in retainer (38) and install on firewall (27) with two screws (39) and new
locknuts (26).
Install floodlight wiring harness (17) and lead (37) on cab floor (36) with three ClampS (33),
17.
screws (32), new lockwashers (35), and new locknuts (34).
18.
Install floodlight wiring harness lead (17) to frame rail (22) with four clamps (19), screws (20),
and new locknuts (18).
FOLLOW-ON TASKS:Z Install toolbox (para. 11-29).
Connect battery ground cable (para. 4-48).
q Check floodlight operation (TM 9-2320-260-10).