HOT WATER PERSONNEL HEATER DOES NOT OPERATE OR DOES NOT OPERATE IN LOW POSITION
PERSONNEL FUEL BURNING HEATER INOPERATIVE

TM-9-2320-260-20 5-Ton 6x6 M809 Series Trucks (Diesel) Truck Cargo: 5-Ton 6x6 M813 (2320-00-050-8902) (EIC:BSB); Manual
Page Navigation
  243    244    245    246    247  248  249    250    251    252    253  
TM 9-2320-260-20
Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 4. Test personnel heater for power input.
Step 1. Ensure heater switch is in HIGH position.
Step 2. Set multimeter to a range that will measure 24 volts.
Step 3. Disconnect lead 400 from personnel heater.
Step 4. Touch positive lead of multimeter to contact end of lead 400.
Step 5. Touch negative lead of multimeter to frame ground. Voltage should be present.
a. Repair or replace lead 400 if voltage is not present (para. 4-52).
b. Replace personnel heater if voltage is present and personnel heater fails to operate
(para. 14-10).
Test 5. Test blower motor resistor.
Step 1. Set multimeter to RX1 scale.
Step 2. Ensure heater switch is set to LOW position.
Step 3. Touch positive lead of multimeter to one lead on resistor.
Step 4. Touch negative lead of multimeter to the other lead on resistor.
Multimeter should measure between 4.5 and 5.5 ohms.
Redate resistor if resistance is not within tolerance of 4.5 and 5.5 ohms
(para. 14-13).
END OF TESTING!