TM 11-7440-293-14
4-83. REMOVING/INSTALLING KEY GENERATOR RACK. (CONT)
ACTION
REMARKS
ITEM
LOCATION
INSTALLATION
Key generator
1.
Roadside on top
equipment table and aline holes.
rack (1) and
of electronic
electronic equip-
equipment table
ment table (2)
Install, handtighten.
2.
Lower supports on
Screw (3), flat
There are four screws. Step 2 is
washers (4) and
key generator rack
typical for all four screws.
nut (5)
Do step 2 again.
3.
Screw holes (6)
Install, handtighten.
Screw (7), lock-
4.
washer (8) and
flat washer (9)
Install, handtighten.
Screw (10), lock-
5.
washer (11) and
flat washer (12)
NOTE
Using two 1/2-inch box wrenches, tighten all screws.
4-inch ground
6. Lower supports
straps
NOTE
See TM 11-7440-251-10 and TM 11-7440-253-10-1 for
installation of key generator and power distri-
of 30-inch grounding strap.
4-174